openwrt/target/linux/qualcommax/patches-6.6/0003-v6.2-thermal-drivers-t...

102 lines
3.5 KiB
Diff

From 7805365fee582056b32c69cf35aafbb94b14a8ca Mon Sep 17 00:00:00 2001
From: Robert Marko <robimarko@gmail.com>
Date: Fri, 19 Aug 2022 00:02:43 +0200
Subject: [PATCH] thermal/drivers/tsens: Allow configuring min and max trips
IPQ8074 and IPQ6018 dont support negative trip temperatures and support
up to 204 degrees C as the max trip temperature.
So, instead of always setting the -40 as min and 120 degrees C as max
allow it to be configured as part of the features.
Signed-off-by: Robert Marko <robimarko@gmail.com>
Reviewed-by: Bjorn Andersson <bjorn.andersson@linaro.org>
Link: https://lore.kernel.org/r/20220818220245.338396-3-robimarko@gmail.com
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
---
drivers/thermal/qcom/tsens-8960.c | 2 ++
drivers/thermal/qcom/tsens-v0_1.c | 2 ++
drivers/thermal/qcom/tsens-v1.c | 2 ++
drivers/thermal/qcom/tsens-v2.c | 2 ++
drivers/thermal/qcom/tsens.c | 4 ++--
drivers/thermal/qcom/tsens.h | 4 ++++
6 files changed, 14 insertions(+), 2 deletions(-)
--- a/drivers/thermal/qcom/tsens-8960.c
+++ b/drivers/thermal/qcom/tsens-8960.c
@@ -273,6 +273,8 @@ static struct tsens_features tsens_8960_
.adc = 1,
.srot_split = 0,
.max_sensors = 11,
+ .trip_min_temp = -40000,
+ .trip_max_temp = 120000,
};
struct tsens_plat_data data_8960 = {
--- a/drivers/thermal/qcom/tsens-v0_1.c
+++ b/drivers/thermal/qcom/tsens-v0_1.c
@@ -553,6 +553,8 @@ static struct tsens_features tsens_v0_1_
.adc = 1,
.srot_split = 1,
.max_sensors = 11,
+ .trip_min_temp = -40000,
+ .trip_max_temp = 120000,
};
static const struct reg_field tsens_v0_1_regfields[MAX_REGFIELDS] = {
--- a/drivers/thermal/qcom/tsens-v1.c
+++ b/drivers/thermal/qcom/tsens-v1.c
@@ -277,6 +277,8 @@ static struct tsens_features tsens_v1_fe
.adc = 1,
.srot_split = 1,
.max_sensors = 11,
+ .trip_min_temp = -40000,
+ .trip_max_temp = 120000,
};
static const struct reg_field tsens_v1_regfields[MAX_REGFIELDS] = {
--- a/drivers/thermal/qcom/tsens-v2.c
+++ b/drivers/thermal/qcom/tsens-v2.c
@@ -35,6 +35,8 @@ static struct tsens_features tsens_v2_fe
.adc = 0,
.srot_split = 1,
.max_sensors = 16,
+ .trip_min_temp = -40000,
+ .trip_max_temp = 120000,
};
static const struct reg_field tsens_v2_regfields[MAX_REGFIELDS] = {
--- a/drivers/thermal/qcom/tsens.c
+++ b/drivers/thermal/qcom/tsens.c
@@ -573,8 +573,8 @@ static int tsens_set_trips(struct therma
dev_dbg(dev, "[%u] %s: proposed thresholds: (%d:%d)\n",
hw_id, __func__, low, high);
- cl_high = clamp_val(high, -40000, 120000);
- cl_low = clamp_val(low, -40000, 120000);
+ cl_high = clamp_val(high, priv->feat->trip_min_temp, priv->feat->trip_max_temp);
+ cl_low = clamp_val(low, priv->feat->trip_min_temp, priv->feat->trip_max_temp);
high_val = tsens_mC_to_hw(s, cl_high);
low_val = tsens_mC_to_hw(s, cl_low);
--- a/drivers/thermal/qcom/tsens.h
+++ b/drivers/thermal/qcom/tsens.h
@@ -499,6 +499,8 @@ enum regfield_ids {
* with SROT only being available to secure boot firmware?
* @has_watchdog: does this IP support watchdog functionality?
* @max_sensors: maximum sensors supported by this version of the IP
+ * @trip_min_temp: minimum trip temperature supported by this version of the IP
+ * @trip_max_temp: maximum trip temperature supported by this version of the IP
*/
struct tsens_features {
unsigned int ver_major;
@@ -508,6 +510,8 @@ struct tsens_features {
unsigned int srot_split:1;
unsigned int has_watchdog:1;
unsigned int max_sensors;
+ int trip_min_temp;