1
0
mirror of https://git.openwrt.org/openwrt/openwrt.git synced 2024-06-26 09:37:29 +02:00
openwrt/target/linux/ramips/patches-4.4/0006-MIPS-ralink-add-cpu-frequency-scaling.patch
Felix Fietkau d041e8b44b ramips: add linux 4.4 support, update mt7621 subtarget to 4.4
Signed-off-by: Felix Fietkau <nbd@openwrt.org>

SVN-Revision: 48951
2016-03-07 16:33:34 +00:00

94 lines
2.6 KiB
Diff

From bd30f19a006fb52bac80c6463c49dd2f4159f4ac Mon Sep 17 00:00:00 2001
From: John Crispin <blogic@openwrt.org>
Date: Sun, 28 Jul 2013 16:26:41 +0200
Subject: [PATCH 06/53] MIPS: ralink: add cpu frequency scaling
This feature will break udelay() and cause the delay loop to have longer delays
when the frequency is scaled causing a performance hit.
Signed-off-by: John Crispin <blogic@openwrt.org>
---
arch/mips/ralink/cevt-rt3352.c | 38 ++++++++++++++++++++++++++++++++++++++
1 file changed, 38 insertions(+)
--- a/arch/mips/ralink/cevt-rt3352.c
+++ b/arch/mips/ralink/cevt-rt3352.c
@@ -29,6 +29,10 @@
/* enable the counter */
#define CFG_CNT_EN 0x1
+/* mt7620 frequency scaling defines */
+#define CLK_LUT_CFG 0x40
+#define SLEEP_EN BIT(31)
+
struct systick_device {
void __iomem *membase;
struct clock_event_device dev;
@@ -36,9 +40,26 @@ struct systick_device {
int freq_scale;
};
+static void (*systick_freq_scaling)(struct systick_device *sdev, int status);
+
static int systick_set_oneshot(struct clock_event_device *evt);
static int systick_shutdown(struct clock_event_device *evt);
+static inline void mt7620_freq_scaling(struct systick_device *sdev, int status)
+{
+ if (sdev->freq_scale == status)
+ return;
+
+ sdev->freq_scale = status;
+
+ pr_info("%s: %s autosleep mode\n", systick.dev.name,
+ (status) ? ("enable") : ("disable"));
+ if (status)
+ rt_sysc_w32(rt_sysc_r32(CLK_LUT_CFG) | SLEEP_EN, CLK_LUT_CFG);
+ else
+ rt_sysc_w32(rt_sysc_r32(CLK_LUT_CFG) & ~SLEEP_EN, CLK_LUT_CFG);
+}
+
static int systick_next_event(unsigned long delta,
struct clock_event_device *evt)
{
@@ -99,6 +120,9 @@ static int systick_shutdown(struct clock
sdev->irq_requested = 0;
iowrite32(0, systick.membase + SYSTICK_CONFIG);
+ if (systick_freq_scaling)
+ systick_freq_scaling(sdev, 0);
+
return 0;
}
@@ -114,15 +138,29 @@ static int systick_set_oneshot(struct cl
iowrite32(CFG_EXT_STK_EN | CFG_CNT_EN,
systick.membase + SYSTICK_CONFIG);
+ if (systick_freq_scaling)
+ systick_freq_scaling(sdev, 1);
+
return 0;
}
+static const struct of_device_id systick_match[] = {
+ { .compatible = "ralink,mt7620-systick", .data = mt7620_freq_scaling},
+ {},
+};
+
static void __init ralink_systick_init(struct device_node *np)
{
+ const struct of_device_id *match;
+
systick.membase = of_iomap(np, 0);
if (!systick.membase)
return;
+ match = of_match_node(systick_match, np);
+ if (match)
+ systick_freq_scaling = match->data;
+
systick_irqaction.name = np->name;
systick.dev.name = np->name;
clockevents_calc_mult_shift(&systick.dev, SYSTICK_FREQ, 60);