diff --git a/target/linux/kirkwood/base-files/etc/init.d/hwmon_fancontrol b/target/linux/kirkwood/base-files/etc/init.d/hwmon_fancontrol index c64ed1100c..334a2a08ef 100755 --- a/target/linux/kirkwood/base-files/etc/init.d/hwmon_fancontrol +++ b/target/linux/kirkwood/base-files/etc/init.d/hwmon_fancontrol @@ -27,10 +27,22 @@ boot() { ;; zyxel,nsa310b) path_to_hwmon='/sys/devices/platform/ocp@f1000000/f1011000.i2c/i2c-0/0-002e/hwmon/hwmon0' - echo 2 > "$path_to_hwmon/pwm1_enable" # fan is on pwm1 - echo 1 > "$path_to_hwmon/pwm1_auto_channels" # temp1 is the only one that changes - echo 23000 > "$path_to_hwmon/temp1_auto_temp_min" - echo 43000 > "$path_to_hwmon/temp1_auto_temp_max" # next step is 49600 millicelsius, or 50 celsius, 43 celsius is better + # use the max. value of (temp1) OR (temp2) OR (temp3) as an input + # for the PWM of the cooling fan + echo 123 > "$path_to_hwmon/pwm1_auto_channels" + # Temperature sensor #1 placed on mainboard + echo 30000 > "$path_to_hwmon/temp1_auto_temp_min" + echo 49600 > "$path_to_hwmon/temp1_auto_temp_max" + # Temperature sensor #2 placed on mainboard + # range: 0 to 127000 in steps of 1000 [millicelsius] + echo 30000 > "$path_to_hwmon/temp2_auto_temp_min" + # range: 0 to 127000 in steps of ???? [millicelsius] + echo 49600 > "$path_to_hwmon/temp2_auto_temp_max" + # Temperature sensor #3 placed close to a chipset + # range: 0 to 60000 in steps of 1000 [millicelsius] + echo 23000 > "$path_to_hwmon/temp3_auto_temp_min" + # pre-defined steps: 103000, 122000, 143300, 170000 in [millicelsius] + echo 103000 > "$path_to_hwmon/temp3_auto_temp_max" ;; esac }