dbd8607b53 upgrade.html: Rename uploaded firmware before sysupgrade
At the moment sysupgrade via WebUI is broken on many devices.
This is reproducible: While the (few) status messages seem
normal, the device boots again with the old firmware.
Sysupgrade via SSH always works.

The sysupgrade call in upgrade.html directly uses the path of
the uploaded firmware file as argument. From several tests and
based on caught stdout/stderr from this line, it looks like haserl
deletes the uploaded firmware file due to a hidden trigger before
or even while it is processed by sysupgrade.

The easiest way to work around that is to just rename the file
before using it as argument to sysupgrade. This will preserve the
file DURING sysupgrade. If sysupgrade fails explicitly (status
code != 0), remove the file to provide sufficient memory for
another upload.

Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Reviewed-by: Fabian Bläse <fabian@blaese.de>
Reviewed-by: Robert Langhammer <rlanghammer@web.de>
2019-05-31 17:18:18 +02:00
518c0d6fef fff-sysupgrade/fff-web: Free cache before upgrade
This might reduce the chance to break devices with 32 MB RAM
during sysupgrade.

Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Reviewed-by: Fabian Bläse <fabian@blaese.de>
2019-04-15 15:54:18 +02:00
37c634ba7c Remove double equals.
== is a bash specific alias for = , and
should not be used in #!/bin/sh scripts. Not in #!/usr/bin/haserl scripts
either, where the shell defaults to /bin/sh.

Signed-off-by: Robert Langhammer <rlanghammer@web.de>
Reviewed-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Reviewed-by: Tim Niemeyer <tim@tn-x.org>
- rebased
Signed-off-by: Tim Niemeyer <tim@tn-x.org>
2018-07-26 21:57:34 +02:00
8297da7051 fff-web: Fix style and XHTML conformity in upgrade.html
Signed-off-by: Adrian Schmutzler <freifunk@adrianschmutzler.de>
Reviewed-by: Christian Dresel <fff@chrisi01.de>
2017-11-12 17:26:43 +01:00
Steffen Pankratz
bd3eb5eb53 Use official OpenWrt project name spelling.
Signed-off-by: Steffen Pankratz <kratz00@gmx.de>
Reviewed-by: Jan Kraus <mayosemmel@gmail.com>
Reviewed-by: Tim Niemeyer <tim@tn-x.org>
2016-08-13 18:19:07 +02:00
Jan Kraus
7f61381272 Changed description of upgrade function in WebUI
Flashing of stock firmware is different for different devices.
At least on TP-Link Images it's not working via sysupgrade.

Signed-off-by: Jan Kraus <mayosemmel@gmail.com>
Reviewed-by: Christian Dresel <fff@chrisi01.de>
Reviewed-by: Tim Niemeyer <tim@tn-x.org>
2016-07-16 09:23:47 +02:00
Dominik Heidler
6c564588ec Add new WebUI
Signed-off-by: Dominik Heidler <dominik@heidler.eu>
Reviewed-by: Tim Niemeyer <tim@tn-x.org>
2016-03-14 21:26:49 +01:00